loading

ODM rugged tablets, handhelds, and tailored mobile computing solutions for industrial applications.

Using Thermal Imaging Handheld Terminals for Equipment Inspection and Early Fault Detection

The use of this thermal imaging handheld terminal enables you to monitor temperatures of the equipment, take thermal images, record the findings, and send the findings to the maintenance system using only one reliable device. When used on a frequent basis, it enables your team to detect overheating issues concerning motors, bearings, and electrical connections in advance. The aim is having an efficient inspection method.

Why Equipment Often Runs Hot Before It Fails

The failure of equipment rarely occurs without prior indication. Prior to a motor seizing or a breaker tripping, there is always a period where something has been working at a higher temperature than it is supposed to be. This is due to the fact that friction, wear, poor connections, and overloading generate additional heat. The problem lies in the fact that heat is difficult to detect by sight.

Common heat warning signs

A few places tend to show trouble first:

Electrical connections. Looseness or corrosion in an electrical connector creates resistance and heats up the area. It’s common for one phase to be heated more than the other two phases.

Motors and bearings. It’s common for one phase to be heated more than the other two phases.

Belts, gearboxes, and conveyors. A worn and under-lubricated bearing may run warm compared to a similar one beside it.

Panels, fuses, and breakers. Overheating occurs long before the circuits blow.

Why routine visual checks miss them

A walkaround inspection does well in identifying leaks, noise, and smells of burning. But once the burning smell has been identified, the problem is usually beyond repair. The single-point thermometers give a value without an image and paper records get lost easily. The end result is that people react to problems rather than plan for them.

A Simple Inspection Routine You Can Start With

You don’t have to employ a massive application system to benefit from thermal imaging. Begin with a small route and do the same thing every single time you perform the inspection.

Choose your checkpoints and set a baseline

Select ten to twenty pieces of equipment that will be significantly affected if they fail: prime mover motors, electric panels, pumps, gearboxes, and important conveyor drives. For the first run, document what "normal" is under normal loads. Your baselines will serve as the standard for future checks.

Comparing similar equipment side by side also helps. If three identical motors run the same load and one is clearly warmer, that is worth a closer look, even without a baseline.

If you want a reference point for “how much warmer is too warm,” many electrical maintenance teams look to the NETA Maintenance Testing Specifications. The NETA guidelines suggest comparing the component with another similar component subjected to similar loading, since the ambient temperature fluctuates quite considerably over the duration of time. For instance, a temperature differential ranging from around 4°C to 15°C is considered cautionary, while any value above 15°C is regarded as alarming. NETA’s wording for a difference above 15°C is “major discrepancy; repair immediately.” Load also matters: NETA suggests scanning with the equipment running at 40% load or more, so a reading taken at light load can hide a real problem.

Use this information to identify an initial problem, not a time-to-failure indicator. The temperature difference will not provide insight on how much time the component has left until it breaks down. These ranges are written mainly for electrical connections and components. For motors, bearings, and other mechanical parts, use the manufacturer’s limits and your own inspection history, and check the current edition of the standard and your site rules before setting alarm levels.

Take readings the same way every time

Do your best to keep the distance, the angle, and the load similar for each test. Note the ambient conditions if there is a significant difference between each round. An ambient condition that is measured at a long distance and an extreme angle cannot be compared to one taken at a shorter distance.

A simple tip is to mark the spot where the inspector should stand, or keep a reference photo in the checklist.

Record, compare, and decide what happens next

Save each thermal photo with the asset name, date, and temperature. Then compare it with the last round. Many teams use a plain three-level system:

Normal: in accordance with the baseline or similar equipment

Watch: slightly warm, but below the 4°C threshold. Verify on the next round and monitor the trend.

Plan a repair: between 4°C to 15°C higher than similar equipment. Arrange for the repair and verify under proper loading.

Act now: more than 15°C higher than similar equipment. Consider as an urgent issue and notify the concerned person.

Agree in advance who gets notified at each level. A finding that nobody sees does not prevent a failure.

an inspector walking an inspection route, taking a thermal photo of a motor or electrical panel

What a Thermal Imaging Handheld Terminal Adds to Everyday Inspection

A routine only works if it is easy to follow on a busy shift. That is where the tool matters.

More than a thermal camera

The standard thermal camera gives a heat image. The thermal imaging handheld terminal integrates the heat image, regular image, checklist, and your notes in one rugged portable device.

Depending on the model, it can also read a barcode or RFID tag to identify the asset. It reduces the number of tools to carry and things to forget.

Ruggedness matters here too. Inspection routes often include dust, rain, gloves, drops, and low light. A device that survives the route is a device that actually gets used.

Connecting field readings to your maintenance system

Heat images are only useful if they can be saved, compared, and reused. One project from SWELL shows why this matters.

The customer was using a conventional thermal imaging camera for outdoors viewing, building inspection, maintenance work, and security patrol. It was performing well in terms of displaying heat, but there was no connectivity to a network, it was a closed system, their own application could not be installed, and it could not generate reports and share field data with their CRM. The real issue was that the data collected in the field could not be recorded, analyzed, or reused.

To test a better approach, SWELL provided a V950 sample unit, a rugged Android handheld with thermal imaging and night vision. The customer used it to check how thermal imaging, their own app, photo capture, data collection, and result uploading could work together on one device. Their product direction shifted from a standalone thermal imager to a mobile terminal that feeds field data into reports and backend systems. You can read the full story in the Thermal Imaging Rugged Mobile Computer for Field Data Collection and Reporting case.

simple workflow diagram

Common Mistakes That Cause False Alarms or Missed Faults

Thermal imaging is easy to get started but easy to misinterpret as well. Here are the three mistakes that lead to such a problem.

Reflections, shiny surfaces, and distance

The highly reflective metallic surface can reflect heat from another source and give an incorrect reading. A small target viewed from a distance can also show up cooler because it blends in with its surroundings. If you suspect anything strange, move closer, change the angle or compare the reading with a similar one taken on a painted or non-reflective surface.

One-off readings and equipment under light load

A device operating at a light load can be OK, and a fault might become visible only during high load. Take comparable readings at comparable loads and verify suspicious readings twice before making any conclusions. One picture is just a hint.

Photos without context

Without an asset name, date, and load conditions, the thermal image is difficult to reference later on. Make it part of the checklist so that the inspector does not have to remember it.

How to Choose a Handheld Thermal Inspection Tool and a Reliable Supplier

Now that the procedure is established, the next question is what equipment and who will do the job. A good thermal inspection equipment manufacturer should be able to help with that question as well.

Features that matter in the field

Image quality and range. Make sure the thermal resolution and temperature range fit your equipment, whether that is electrical panels or hotter process machinery.

Readable display. The screen should be easy to read in sunlight and usable with gloves.

Battery. It should last a full shift. A swappable battery is a practical advantage on long routes.

Protection you can verify. Ask for the dust, water, and drop ratings, and how they were tested.

An open system. Check whether you can run your own app, export data, and connect to your maintenance or ERP system.

Questions to ask a thermal inspection manufacturer

Do I get to try out the sample using my own equipment before making an order?

What is the software solution like: SDK, API, or custom app?

How do I calibrate and test the thermal module?

What post-delivery support is offered, such as firmware updates, accessories, and spare parts?

What is the usual time of delivery of samples and of the product itself?

When customization makes sense

If you represent a brand, if you are a system integrator or have a special workflow, than the standard device is not for you. You will be able to use ODM or OEM way of work — modification of housing and interface, addition of special modules such as barcode, RFID or NFC modules, as well as software and logo. Since 2009 SWELL manufactures robust devices and can provide the described type of cooperation. More details are on the customized solutions page and the thermal imaging rugged handheld terminal category page.

factory testing and quality-check photo

Conclusion

Early fault detection does not rely on expensive machinery. Early fault detection relies on a process that is consistent, documented, and acted upon. A thermal imaging handheld terminal makes this process easier because all of that information is stored in one place. If you wish to try this out on your own machinery, the SWELL team will be happy to help tailor this for you. Learn more about our thermal imaging rugged handheld terminals.

FAQ

What is the difference between a thermal camera and a thermal imaging handheld terminal?

A thermal camera is used to take images of heat. A handheld terminal is a complete computer that is portable and has thermal imaging capability so that applications, asset tagging, notes, and data uploads are also possible.

Can thermal inspection replace scheduled maintenance checks?

Not at all. Its application is highly advisable along with other maintenance practices. Thermal vision reflects the temperature changes while some failures such as lubrication or inner wear might require additional checking procedures such as vibration analysis and others.

What equipment is best suited to thermal inspection?

Most likely the electrical panels, connections, motors, bearings, pumps, gearboxes, and conveyor drives are used as they usually generate heat when there is a failure. The problems that don't change the temperature of operation are less obvious.

Can I use my own inspection app on the device?

It depends on the type and operating system of the terminal you are going to buy. Usually Android terminals support the installation of your app after the testing phase.

What should I prepare before asking a manufacturer for a sample or custom version?

The list of inspected equipment types, the work environment, current inspection procedure, software system, quantities, and certification in your local market.

prev
How Reading Range Antenna Design and Tag Read Rate Guide Your UHF RFID Handheld Reader Choice
recommended for you
Get in touch with us
CONTACT US
Telephone: + 86-755-29031883
Phone/WhatsApp: +86 13662225948

Shenzhen: 8F, Building A, Zhihui Innovation Center, Hang Cheng Industrial Zone, Bao 'an District, Shenzhen, China

Hong Kong: Room605, 6/F, FA Yuen Commercial Building, 75-77 FA Yuen Street, MongKok, Kowloon, Hong Kong.

+ 86-755-29031883

SWELL is an ODM-focused rugged mobile device partner for industrial applications.

Contact us
whatsapp
Contact customer service
Contact us
whatsapp
cancel
Customer service